• Customized Conductor AAC for Power Transmission Project
  • Customized Conductor AAC for Power Transmission Project
  • Customized Conductor AAC for Power Transmission Project
  • Customized Conductor AAC for Power Transmission Project
  • Customized Conductor AAC for Power Transmission Project
  • Customized Conductor AAC for Power Transmission Project

Customized Conductor AAC for Power Transmission Project

Application: Construction, Overhead, Underground, Industrial, Power Station, Telecommunication
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Samples:
US$ 0.25/Meter 1 Meter(Min.Order)
| Order Sample
BARE CONDUCTOR
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Customized Conductor AAC for Power Transmission Project pictures & photos
Customized Conductor AAC for Power Transmission Project
US $0.24-0.83 / Meter
Min. Order: 1,000 Meters

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
AAC -BS-ASTM-IEC-AS
Insulation Material
Bare
Sheath Material
Bare
Material Shape
Round Wire
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS, VDE, TUV
Model
Zs-AAC16-5-108
Brand
Dayuan
Supplier′s Nature
Manufacturer
Certificate
ISO, TUV, CCC, IEC
Standard of Other Country
CSA IEC, ASTM, DIN, BS, GOST, Sas Standard.
Independent Lab
Yes
OEM/ODM
Ok
Delivery Time
7 Workdays
Conductor
Stranded
Transport Package
Wooden Drum, as Request
Specification
IEC, ISO, GB, TUV, CCC
Trademark
SANWU CABLE
Origin
Henan, China
HS Code
7614100000
Production Capacity
100000m/Day, 100000 M/Day

Packaging & Delivery

Package Size
1100.00cm * 1100.00cm * 900.00cm
Package Gross Weight
1500.000kg

Product Description

Customized Conductor AAC for Power Transmission Project

Applications:
Conductor(AAC, AAAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
Customized Conductor AAC for Power Transmission Project
Customized Conductor AAC for Power Transmission Project
Customized Conductor AAC for Power Transmission Project



 Material Standard:
 1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
 2) The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
 3) Production can be arranged according to customers requirements for material standard,etc.
 Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced

 Standards:
 ASTM-B232   Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
 BS215-2         aluminum conductors steel-reinforced -For overhead power transmission
 DIN48204      Steel reinforced aluminum stranded conductors
 IEC209           Aluminum stranded conductor steel reinforced
                       Customized type available.
 
 ACSR bare conductor meets/exceeds the following ASTM specifications:
        B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
        B-231 Aluminum Conductors, Concentric-Lay-Stranded 
        B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced      
 (ACSR)
        B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel 
        Reinforced (ACSR/AZ)
        B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced 
       (ACSR/AZ) 
        B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum 
       Conductors, Steel Reinforced (ACSR)

 Technical characteristics:
 Executive Standard:BS

Code nam e
Conductor Size (AWG/MCM) diam eter of w ires (m m ) Cr os s -s ectional Area
(m m 2)
Overall diam eter
(m m )
Weight (k g/k m ) Break ing load D.C. Res is tance at 20ºC
(ohm /k m )
k gf k N
Midge 22 7/2.06 23..33 6.18 64 407 3.99 1.2249
Aphis 25 3/3.35 26.44 7.22 74 420 4.12 1.105
Gnat 25 7/2.21 26.85 6.63 74 468 4.59 1.0643
Weevil 30 3/3.66 31.56 7.89 88 495 4.86 0.9357
Mosquito 35 7/2.59 36.88 7.77 101 614 6.03 0.7749
Ladybird 40 7/2.79 42.8 8.37 117 701 6.87 0.6678
Ant 50 7/3.10 52.83 9.3 145 844 8.28 0.5409
Fly 60 7/3.40 63.55 10.2 174 1010 9.9 0.4497
Bluebottle 70 7/3.66 73.65 10.98 202 1156 11.33 0.388
Earw ig 75 7/3.78 78.55 11.34 215 1217 11.94 0.3638
Grasshopper 80 7/3.91 84.05 11.73 230 1303 12.78 0.34
Clegg 90 7/4.17 95.6 12.51 262 1482 14.53 0.2989
Wasp 100 7/4.39 106 13.17 290 1633 16.01 0.2697
Beetle 100 19/2.67 106.4 13.35 293 1773 17.39 0.2701
Bee 125 7/4.90 132 14.7 361 2033 19.94 0.2165
Cricket 150 7/5.36 157.9 16.08 432 2432 23.85 0.1813
Hornet 150 19/3.25 157.6 16.25 434 2519 24.7 0.1823
Caterpilar 175 19/3.53 185.9 17.65 511 2917 28.61 0.1546
Chafer 200 19/3.78 213.2 18.9 587 3305 32.41 0.1348
Spider 225 19/3.99 237.6 19.95 654 3683 36.12 0.121
Cockroach 250 19/4.22 265.7 21.1 731 4118 40.39 0.1081
Butterfly 300 19/4.65 322.7 23.25 888 4970 48.74 0.0891
Moth 350 19/5.00 373.1 25 1027 5746 56.36 0.077
Drone 350 37/3.58 372.4 25.06 1027 5844 57.31 0.0774
Locust 400 19/5.36 428.7 26.8 1180 6603 64.76 0.0671
Centipede 400 37/3.78 415.2 26.46 1145 6435 63.11 0.0695
Maybug 450 37/4.09 486.1 28.63 1340 7535 73.89 0.0593
Scorpion 500 37/4.27 529.8 29.89 1461 8160 80.03 0.0544
Cicada 600 37/4.65 628.3 32.55 1732 9678 94.9 0.0459
Tarantula 750 37/5.23 794.9 36.61 2192 12244 120.07 0.0363

Executive Standard:DIN
Conductor Size (AWG/MCM) diam eter of w ires (m m ) Cr os s -s ectional Area
(m m 2)
Overall diam eter
(m m )
Weight (k g/k m ) Break ing load D.C. Res is tance at 20ºC
(ohm /k m )
k gf k N
16 7/1.70 15.89 5.1 43 290 2.84 1.8017
25 7/2.10 24.25 6.3 66 425 4.17 1.1806
35 7/2.50 34.36 7.5 94 589 5.78 0.8332
50 7/3.00 49.48 9 135 810 7.94 0.5786
50 19/1.80 48.35 9 133 862 8.45 0.595
70 19/2.10 65.81 10.5 181 1154 11.32 0.4371
195 19/2.50 93.27 12.5 256 1599 15.68 0.3084
120 19/2.80 117 14 322 1915 18.78 0.2459
150 37/2.25 147.1 15.75 406 2580 25.3 0.196
185 37/2.50 181.6 17.5 500 3114 30.54 0.1588
240 61/2.25 242.5 20.25 670 4029 39.51 0.1192
300 61/2.50 299.4 22.5 827 4864 47.7 0.09651
400 61/2.89 400.1 26.01 1104 6206 60.86 0.7222
500 61/3.23 499.8 29.07 1379 7614 74.67 0.05782
625 61/2.96 626.2 32.56 1732 9713 95.25 0.04625
800 91/3.35 802.1 36.85 2218 12072 118.39 0.0361
1000 91/3.74 999.7 41.14 2767 14863 145.76 0.02897

 Executive Standard:ASTM

Code nam e
Conductor Size (AWG/MCM) diam eter of w ires (m m ) Cr os s - s ectional
Area (m m 2)
Overall diam eter
(m m )

Weight (k g/k m )
Break ing load D.C. Res is tance at 20ºC
(ohm /k m )
k gf k N
Peachbell 6 7/1.55 13.21 4.65 36 254 2.49 2.175
Rose 4 7/1.96 21.12 5.88 58 399 3.91 1.361
Iris 2 7/2.47 33.54 7.41 92 611 5.99 0.8568
Pansy 1 7/2.78 42.49 8.34 117 746 7.31 0.6763
Poppy 1/0 7/3.12 53.52 9.36 148 903 8.86 0.5369
Aster 2/0 7/3.50 67.35 10.5 186 1136 11.14 0.4267
Phlox 3/0 7/3.93 84.91 11.79 234 1375 13.48 0.3384
Oxlip 4/0 7/4.42 107.4 13.26 296 1740 17.06 0.2676
Sneezew ort 250 7/4.80 126.7 14.4 349 2052 20.12 0.2268
Valerian 250 19/2.91 126.4 14.55 348 2107 20.66 0.2273
Daisy 266.8 7/4.96 135.3 14.88 373 2191 21.49 0.2124
Laurel 266.8 19/3.01 135.2 15.05 373 2254 22.1 0.2125
Peony 300 19/3.19 151.9 15.95 419 2482 24.34 0.1892
Tulip 336.4 19/3.38 170.5 16.9 470 2787 27.33 0.1685
Daffodil 350 19/3.45 177.6 17.25 490 2903 28.47 0.1618
Canna 397.5 19/3.68 202.1 18.4 557 3237 31.74 0.1422
Goldentuft 450 19/3.91 228.1 19.55 629 3580 35.11 0.126
Cosmos 477 19/4.02 241.2 20.1 665 3784 37.11 0.1191
Syringa 477 37/2.88 241 20.16 664 3932 38.56 0.1192
Hyacinth 500 37/2.95 252.9 20.65 697 4126 40.46 0.1136
Zinnia 500 19/4.12 253.3 20.6 698 3975 38.98 0.1134
Dahlia 556.5 19/4.35 282.4 21.75 779 4431 43.45 0.1018
Mistletoe 556.5 37/3.11 181.1 21.77 775 4496 44.09 0.1022
Meadow sw eet 600 37/3.23 303.2 22.61 836 4849 47.55 0.09477
Orchid 636 37/3.33 322.2 23.31 888 5154 50.54 0.08919
Heuchera 650 37/3.37 330 23.59 910 5279 51.77 0.08708
Verbena 700 37/3.49 354 24.43 976 5661 55.52 0.08117
Flag 700 61/2.72 354.5 24.48 977 5831 57.18 0.081
Violet 715.5 37/3.53 362.1 24.71 998 5792 56.8 0.0794
Nasturtium 715.5 61/2.75 362.3 24.75 999 5961 58.46 0.0793
Petunia 750 37/3.62 380.8 25.34 1050 5969 58.54 0.0755
Cattail 750 61/2.82 381 25.38 1050 6147 60.28 0.0754
Arbutus 795 37/3.72 402.1 26.04 1109 6303 61.81 0.0715
Lilac 795 61/2.90 402.9 26.1 1111 6501 63.75 0.0713
Cockscomb 900 37/3.96 455.7 27.72 1256 9667 68.62 0.0631
Snapdragon 900 61/3.09 457.4 27.81 1261 7236 70.96 0.0628
Magnolia 954 37/4.08 483.7 28.56 1334 7428 72.84 0.0594
Goldenrod 954 61/3.18 484.5 28.62 1336 4664 75.16 0.0593
Haw kw eed 1000 37/4.18 507.7 29.26 1400 7796 76.45 0.0566
Camellia 1000 61/3.25 506 29.25 1395 8005 78.5 0.0568
Bluebell 1033.5 37/4.24 522.4 29.68 1440 8022 78.67 0.055
Larkspur 1033.5 61/3.31 524.9 29.79 1447 8304 81.43 0.0547
Marigold 1113 61/3.43 563.6 30.87 1554 8917 87.45 0.051
Haw thom 1192.5 61/3.55 603.8 31.95 1665 9551 93.66 0.0476

 We can make according to your specifications, customized LOGO, with your company name on the cable.

 Certification:
Customized Conductor AAC for Power Transmission Project
Customized Conductor AAC for Power Transmission Project
Customized Conductor AAC for Power Transmission Project



Package
Wooden drum or 100m/roll
Customized Conductor AAC for Power Transmission Project
Customized Conductor AAC for Power Transmission Project
Customized Conductor AAC for Power Transmission Project

Customer
American, Australia, India, South Africa, South America...
Our Principles

1. Quality first, customer first, safety first
2. Better service, faster delivery
3. Equal and mutual benefit
4. Honest and professional

Why choose us?
1. Swift and professional response
2. Patient and trusty
3. Severe quality control system
4. On-time delivery

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Customized Conductor AAC for Power Transmission Project pictures & photos
Customized Conductor AAC for Power Transmission Project
US $0.24-0.83 / Meter
Min. Order: 1,000 Meters

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
200000000 RMB
Plant Area
>2000 square meters